Welcome to Bicon South Africa Professionals' Site

Literature & Publications
Bicon’s Research focuses on a design that has remained unchanged since 1985. While other manufacturers claim decades of research, most of this research had been conducted on designs that are no longer on the market today. Please find a selection of publications on the Bicon system below.

  1. McDermott, N., Chuang S.K., Woo, V.V., Dodson T.B., Sinus grafting as a risk factor for implant failure, The International Journal of Oral & Maxillofacial Implants, Vol.21, No.3, p. 366-374, May/June 2006.
  1. Yoo, R.H., Chuang, S.K., Erakat, M., Weed, M., Dodson T.B.,Changes in Crestal Bone Levels in the Setting of Immediately Loaded Implants, The International Journal of Oral & Maxillofacial Implants, Vol.21, No.2, p. 253-261, March/April 2006.
  1. Gentile, M., Chuang, S.K., & Dodson, T., Survival Estimates and Risk Factors for Failure with 6 x 5.7 mm Implants, The International Journal of Oral & Maxillofacial Implants, Vol. 20, No. 6, p. 930-937, November/December 2005.
  1. Dibart, S., Warbington, M., Su, M.F., Skobe, Z., In Vitro Evaluation of the Implant-Abutment Bacterial Seal: The Locking Taper System, The International Journal of Oral & Maxillofacial Implants, Vol. 20, No. 5, p. 732-737, September 2005.
  1. Coelho, P.G. , Lemons, J.E., IBAD Nanothick Bioceramic Incorporation on Metallic Implants for Bone Healing Enhancement. From Physico/Chemical Characterization to In-vivo Performance Evaluation, NSTI-Nanotech, Vol. 1, 2005.
  1. Coelho, P.G., Lemons, J.E., Morphological and Chemical Assessment of Two Thin-film Ion Beam Assisted Deposited Bioceramic Coated Surfaces on Ti-6Al-4V Implants, AO Annual Meeting, Orlando, FL, 2005.
  1. Coelho, P.G., Materials Science & Engineering, Birmingham, AL, USA, Geurs, N.C., University of Alabama, Birmingham, USA, Freire, J.N.O., Universidade Federal De Santa Catarina, Florianopolis, Brazil, Coelho, A.L., UNICENP, Curitiba, Brazil, and Speratti, D., Faulkner Hospital, Boston, MA, USA., Gingival Tissue Health Around Locking-Taper Implant-Abutment Connections, IADR General Session; Baltimore, MD.
  1. Dibart, S., Evaluating the Bacterial Seal of an Implant-Abutment Connection, AAP Annual Meeting, Orlando, FL, 2004.
  1. Urdaneta, R., et al. Comparison of the Periodontal Performance of the Integrated Abutment Crowns, Porcelain Fused to Metal Crowns and Teeth: A 2-year retrospective Cohort Study, Oral Presentation OSSEO, September 2004.
  1. Bozkaya, D., and Müftü, S., Muftu, A., Evaluation of Load Transfer Characteristics of Five Different Implant Systems in Compact Bone at Different Load Levels by Finite Element Analysis, Journal of Prosthetic Dentistry, Vol. 92 No.6, p.523-530, December 2004.
More Literature & Publications are available on: www.bicon.com/news/n_publications.html